Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Language
Publication year range
1.
J Fluoresc ; 2023 Aug 19.
Article in English | MEDLINE | ID: mdl-37597134

ABSTRACT

Rapid identification of bacterial species in patient samples is essential for the treatment of infectious diseases and the economics of health care. In this study, we investigated an algorithm to improve the accuracy of bacterial species identification with fluorescence spectroscopy based on autofluorescence from bacteria, and excitation wavelengths suitable for identification. The diagnostic accuracy of each algorithm for ten bacterial species was verified in a machine learning classifier algorithm. The three machine learning algorithms with the highest diagnostic accuracy, extra tree (ET), logistic regression (LR), and multilayer perceptron (MLP), were used to determine the number and wavelength of excitation wavelengths suitable for the diagnosis of bacterial species. The key excitation wavelengths for the diagnosis of bacterial species were 280 nm, 300 nm, 380 nm, and 480 nm, with 280 nm being the most important. The median diagnostic accuracy was equivalent to that of 200 excitation wavelengths when two excitation wavelengths were used for ET and LR, and three excitation wavelengths for MLP. These results demonstrate that there is an optimum wavelength range of excitation wavelengths required for spectroscopic measurement of bacterial autofluorescence for bacterial species identification, and that measurement of only a few wavelengths in this range is sufficient to achieve sufficient accuracy for diagnosis of bacterial species.

2.
Sensors (Basel) ; 22(5)2022 Mar 02.
Article in English | MEDLINE | ID: mdl-35271100

ABSTRACT

An ultra-high-speed computational CMOS image sensor with a burst frame rate of 303 megaframes per second, which is the fastest among the solid-state image sensors, to our knowledge, is demonstrated. This image sensor is compatible with ordinary single-aperture lenses and can operate in dual modes, such as single-event filming mode or multi-exposure imaging mode, by reconfiguring the number of exposure cycles. To realize this frame rate, the charge modulator drivers were adequately designed to suppress the peak driving current taking advantage of the operational constraint of the multi-tap charge modulator. The pixel array is composed of macropixels with 2 × 2 4-tap subpixels. Because temporal compressive sensing is performed in the charge domain without any analog circuit, ultrafast frame rates, small pixel size, low noise, and low power consumption are achieved. In the experiments, single-event imaging of plasma emission in laser processing and multi-exposure transient imaging of light reflections to extend the depth range and to decompose multiple reflections for time-of-flight (TOF) depth imaging with a compression ratio of 8× were demonstrated. Time-resolved images similar to those obtained by the direct-type TOF were reproduced in a single shot, while the charge modulator for the indirect TOF was utilized.

3.
Sci Rep ; 9(1): 9383, 2019 06 28.
Article in English | MEDLINE | ID: mdl-31253820

ABSTRACT

The mechanism underlying tissue fusion mediated by laser irradiation remains unclear. We clarify the mechanisms underlying laser-mediated tissue fusion using a novel model. Microscopic examinations of morphological changes within the adventitia of a bovine carotid artery and a collagen sheet prepared from bovine dermis showed collagen fibril bundle loosening and collagen fibre swelling following heating at 46 °C. An incised bovine carotid artery covered with a collagen sheet to which pressure and laser heat of 40 °C-52 °C were applied created a structure that was pressure resistant to >300 mmHg. Microscopic analyses of the irradiation site showed collagen fibril interdigitation. Hence, low-temperature laser-mediated tissue fusion causes collagen fibril bundles to loosen and swell, and crimping causes the fibres to intertwine. As the temperature declines, the loosened and swollen fibrils and fibres tighten, and collagen fibre interdigitation is completed. This technology could be applied to fuse tissues during surgery.


Subject(s)
Collagen , Lasers , Ligation/methods , Surgical Procedures, Operative/methods , Animals , Arteries/metabolism , Arteries/pathology , Arteries/surgery , Arteries/ultrastructure , Biocompatible Materials , Cattle , Collagen/chemistry , Extracellular Matrix , Hot Temperature/adverse effects , Microscopy
4.
Opt Express ; 24(4): 4155-76, 2016 Feb 22.
Article in English | MEDLINE | ID: mdl-26907065

ABSTRACT

In the work described in this paper, an image reproduction scheme with an ultra-high-speed temporally compressive multi-aperture CMOS image sensor was demonstrated. The sensor captures an object by compressing a sequence of images with focal-plane temporally random-coded shutters, followed by reconstruction of time-resolved images. Because signals are modulated pixel-by-pixel during capturing, the maximum frame rate is defined only by the charge transfer speed and can thus be higher than those of conventional ultra-high-speed cameras. The frame rate and optical efficiency of the multi-aperture scheme are discussed. To demonstrate the proposed imaging method, a 5×3 multi-aperture image sensor was fabricated. The average rising and falling times of the shutters were 1.53 ns and 1.69 ns, respectively. The maximum skew among the shutters was 3 ns. The sensor observed plasma emission by compressing it to 15 frames, and a series of 32 images at 200 Mfps was reconstructed. In the experiment, by correcting disparities and considering temporal pixel responses, artifacts in the reconstructed images were reduced. An improvement in PSNR from 25.8 dB to 30.8 dB was confirmed in simulations.

5.
Lasers Med Sci ; 29(3): 1125-9, 2014 May.
Article in English | MEDLINE | ID: mdl-24241973

ABSTRACT

Currently, laser radiation is used routinely in medical applications. For infrared lasers, bone ablation and the healing process have been reported, but no laser systems are established and applied in clinical bone surgery. Furthermore, industrial laser applications utilize computer and robot assistance; medical laser radiations are still mostly conducted manually nowadays. The purpose of this study was to compare the histological appearance of bone ablation and healing response in rabbit radial bone osteotomy created by surgical saw and ytterbium-doped fiber laser controlled by a computer with use of nitrogen surface cooling spray. An Ytterbium (Yb)-doped fiber laser at a wavelength of 1,070 nm was guided by a computer-aided robotic system, with a spot size of 100 µm at a distance of approximately 80 mm from the surface. The output power of the laser was 60 W at the scanning speed of 20 mm/s scan using continuous wave system with nitrogen spray level 0.5 MPa (energy density, 3.8 × 10(4) W/cm(2)). Rabbits radial bone osteotomy was performed by an Yb-doped fiber laser and a surgical saw. Additionally, histological analyses of the osteotomy site were performed on day 0 and day 21. Yb-doped fiber laser osteotomy revealed a remarkable cutting efficiency. There were little signs of tissue damage to the muscle. Lased specimens have shown no delayed healing compared with the saw osteotomies. Computer-assisted robotic osteotomy with Yb-doped fiber laser was able to perform. In rabbit model, laser-induced osteotomy defects, compared to those by surgical saw, exhibited no delayed healing response.


Subject(s)
Lasers , Optical Fibers , Osteotomy/methods , Robotics , Surgery, Computer-Assisted/methods , Ytterbium/therapeutic use , Animals , Muscles/pathology , Muscles/surgery , Rabbits , Radius/radiation effects , Radius/surgery , Wound Healing
SELECTION OF CITATIONS
SEARCH DETAIL
...